Flexible delivery | Tailored Courses | Nationally Recognised

How to Inspect Emergency Exit Signage at Work

Learn how to inspect emergency exit signage, test illumination and visibility, record defects, and keep evacuation routes safe and ready for your people.
Share this post

A clear exit sign can save valuable seconds when people are trying to leave under pressure. To inspect emergency exit signage properly, look beyond whether a fitting is switched on. Your check needs to confirm that people can see it, understand it and follow it towards a safe exit – including when normal lighting fails.

For workplace leaders, facility managers and emergency control organisation members, this is a practical duty of care task. Exit signage supports your evacuation plan, your wardens and, most importantly, every person who may need to leave the building quickly. A sign hidden by new shelving, a failed battery or an arrow pointing towards a changed layout can turn a familiar workplace into a confusing one.

Why emergency exit signage deserves a real inspection

Emergency exit signs are part of an emergency lighting system, not simply wall décor with a green pictogram. They help occupants identify the direction of travel and locate an exit during a power interruption, smoke event or other evacuation. Their value depends on more than installation. They need to remain visible, illuminated and aligned with the way people actually move through the premises.

Workplaces change constantly. A retail floor may be reset, a tenancy may be refurbished, a storeroom may gain taller racking, or a temporary partition may alter a corridor. These changes can block sightlines or make an existing directional sign misleading. Even a compliant installation can become ineffective if it is not reviewed as the workplace evolves.

The inspection also has a human element. Visitors, contractors, new starters and people who do not use the site every day rely on signs more heavily than experienced staff. If the escape route is not immediately obvious, your evacuation arrangements are asking people to make decisions at the worst possible time.

How to inspect emergency exit signage step by step

Start with your current evacuation plan, floor plan and any previous maintenance records. Walk the route as an occupant would, beginning in work areas, meeting rooms, amenities, storage spaces and any areas used by visitors. Do not limit the check to the final exit door. The direction to that door matters just as much.

Check visibility from the approach route

Stand where a person would naturally enter each corridor, stairwell or open work area. Can they see an exit sign early enough to make a confident choice? Check from different heights and angles, particularly where there are intersections, doorways, suspended displays or changes in floor level.

Look for signs obscured by stock, decorations, banners, open doors, high furniture, temporary equipment or building works. In hospitality, retail and education settings, seasonal displays and activity set-ups can create visibility issues quickly. A sign may still be physically present but fail its purpose if it cannot be seen when people need it.

Also check that the running-man symbol and directional arrow are clear and appropriate. A sign that points left when the safest route is now right needs prompt review. Never assume staff will know what was intended. The sign must communicate the route without explanation.

Confirm the sign is illuminated and legible

During normal operation, inspect each fitting for even illumination, readable pictograms, intact lenses and secure mounting. Look for flickering, dim sections, discolouration, cracked diffusers, loose fittings or moisture damage. Older fittings may appear illuminated but be too dull to provide useful guidance in reduced light.

Pay attention to signs installed near bright windows, reflective surfaces or competing illuminated displays. Glare can reduce legibility. Conversely, signs in dim back-of-house areas must be sufficiently visible without relying on the room’s normal lights.

If a sign is damaged or difficult to read, treat it as a defect rather than a cosmetic issue. Isolate the risk where practical, notify the responsible person and arrange repair by a suitably qualified service provider.

Test operation on emergency power

A critical part of the inspection is confirming that emergency exit signage continues to operate when the normal power supply is interrupted. Depending on the system type, this may involve a test facility, a central battery system or individual self-contained fittings. The appropriate test method, duration and servicing schedule should follow the applicable Australian requirements, manufacturer instructions and your building’s maintenance arrangements.

This is not a task to rush or improvise. An emergency-lighting discharge test can affect multiple fittings and may require planning so the building remains safe throughout the process. In multi-tenanted buildings, base-building systems may be managed by the owner or facilities team, while tenants still need to report faults and ensure their own evacuation routes remain suitable.

When testing, confirm that the sign stays illuminated on emergency supply and that its light output remains useful. A fitting that comes on briefly but fades well before the required duration is not reliable. Record the result, the location and any action taken.

Inspect the exit itself and the path to it

A good sign cannot compensate for a blocked or unsuitable exit route. As you inspect emergency exit signage, look directly beneath it and along the direction it indicates. Are corridors, stairwells and doorways clear of cartons, furniture, cleaning equipment or stored materials? Can doors be opened readily in the direction required for escape? Are fire doors being wedged open or obstructed?

Check that the route remains practical for the people who use it. A path that is clear for office staff may not work for a person using a mobility aid, a parent with a pram in an education-and-care setting, or a worker moving through a noisy warehouse. Where accessibility or special assistance arrangements apply, they should be reflected in your emergency plan and practised through evacuation exercises.

Record defects so they are actually resolved

A quick verbal report is useful, but it is not enough for ongoing control. Keep a simple, traceable record of each inspection. Note the date, location, fitting identification if available, issue found, immediate controls, person notified and completion date for repairs. Photos can help maintenance teams locate a fault and demonstrate what has changed over time.

Assign ownership. If the facilities manager arranges repairs, wardens should know how to escalate urgent concerns. If building management maintains the emergency lighting system, the tenant representative should know who to contact and how the fault will be tracked. Unclear ownership is one of the most common reasons minor defects remain in place for months.

Where a sign failure affects a key route, consider interim measures while repair is arranged. This may include restricting access to an affected area, revising the route communicated to occupants or placing temporary directional guidance where appropriate. Any temporary measure must be visible, understood by wardens and included in the next briefing or drill.

Build signage checks into everyday preparedness

The most effective workplaces do not treat exit signs as a once-a-year compliance item. They include a visual check in routine warden inspections, after fit-outs, following changes to room layouts and before major events. Formal maintenance and testing should be scheduled and documented, while everyday observations are reported as soon as they are noticed.

Evacuation drills provide one of the best reality checks. Watch where people hesitate, turn the wrong way or cluster at a junction. Those moments may reveal that a sign is hidden, a directional arrow is unclear or the evacuation diagram no longer reflects the space. Ask wardens and staff for feedback after the drill, especially those who are new to the site.

Training brings the system together. Wardens need to understand their sweep areas, alternate exits, communication process and the limits of what they should do during an emergency. Staff need to recognise alarms, follow directions and leave without stopping to collect personal belongings. EDS Training Group helps organisations connect these practical behaviours with emergency planning, fire warden capability and evacuation procedures. EDS Training can also perform the testing and compliance of the Exit and Emergency lighting.

Your exit signs should make the next safe action obvious before anyone has time to second-guess it. Keep them visible, maintain them properly and test your routes with real people. Be ready. Stay safe.

Learned something new?

Take the next step and get hands-on with our training.

Contact us to speak with our fire safety experts to discuss how EDS Training Group can support you or workplace’s emergency preparedness.